Atten ADS1042CML Digital Oscilloscope 1Gsa/s 40mhz


Always Free Shipping

ADS1042CML dual-channel color digital storage oscilloscope

Model: ADS1042CML Brand: ATTEN (ATTEN)


1 electronic circuit design and debug

(2) examine the transient signal

3 industrial control measure

4 Quality Control

5 Education and Training

6 maintenance service


Product Weight: 2.4KG

Product size: 339mm * 110.5mm * 148.5mm (L × W × H)

· New slim design, compact, more convenient to carry;
· Color TFT LCD display, waveform display more clear and stable;
· Versatile trigger modes: Edge, Pulse, Video, Slope, Alternate;
Unique digital filter and waveform recorder;
· Pass / Fail function;
· 2Mpts storage depth overview of global and detailed presentation;
• 32 automatic measurements;
• 2 set of reference waveforms, 20 groups of common waveforms, 20 groups set up internal storage / recall; support of waveforms, setups, CSV and bitmap file U-disk external storage and recall;
· 5 kinds of math :+,-,*, FFT;
· Screen saver function (1-5 minutes);
· Manual, tracking, automatic cursor measurement function;
· Channel waveform and FFT waveform at the same time split-screen display;
· Analog waveform mesh screen brightness and brightness adjustable;
· Pop-up menu display mode, the user operation more flexible, natural;
· Rich interface display style: classic, modern, traditional, simple;
· Multilingual interface display, embedded online help, a key storage, one-touch printing functions;
· Standard Interface: USB Host: U disk support U disk storage and the system through software upgrades; USB Device: Support PictBridge direct printing and PC connectivity with remote control; RS-232.

Technical Specifications
Bandwidth: 40MHZ
Number of Channels: Dual Channel +1 external trigger channel
The highest real-time sampling rate: 1GSa / s (single channel), 500MSa / s (dual channel)
Equivalent sampling rate: 25GSa / s
Memory depth: 2Mpts
Rise time: <8.8ns
Input impedance: 1.0M? + / -2% | | 13Pf + /-3pF, 50? + / -2%
Time base range: 10ns/div-50s/div, Roll: 100ms-50s/div
Vertical Sensitivity: 2mv-10v/div (1-2-5 sequence)
Vertical Resolution: 8bit
Display: 7 inch color TFT (480 * 234) LCD

Input coupling: DC, AC, grounding (AC, DC, GND)
Input impedance: 1.0M? + / -2% | | 13Pf + /-3pF, 50? + / -2%
Maximum input voltage: 400V (DC + AC peak, 1M? input impedance), CAT I, CAT II
Probe Attenuation: 1X, 10X
Probe Attenuation Coefficient: 1X, 10X, 100X, 1000X

Signal acquisition system
Sampling Method: Real-time sampling, random sampling
Memory depth: two-channel 2M, 1M per channel
Access modes: sample, peak detection, the average
Average number: 4,16,32,64,128,256

Vertical System
Vertical Sensitivity: 2mV/div - 5V/div (1-2-5 sequence)
Channel offset voltage range: 2mV-100mV: ± 1.6V 102mV-10V: ± 40V
Vertical resolution: 8 bit
Bandwidth: 40MHz
Single Bandwidth: 40MHz
The corresponding low-frequency (AC-coupled,-3dB): ? 10Hz (on the BNC)
DC Gain Accuracy: 5mv/div-10v/div: ? ± 3%
                2mv/div: ? ± 4%
DC measurement accuracy (? 100mv/div): ± [3.0% X (| actual reading | + | vertical displacement readings |) +1% X | vertical displacement readings | +0.2 grid +2 mV]
DC measurement accuracy (> 100mv/div): ± [3.0% X (| actual reading | + | vertical displacement readings |) +1% X | vertical displacement readings | +0.2 cell +100 mV]
Rise time (BNC on the typical values): <8.8ns
Vertical Input Coupling: AC, DC, GND
Math: +, -, *, /, FFT
FFT: window mode, Hanning, Hamming, Blackman, Rectangular; sampling points 1024 points
Bandwidth limitations: 20MHz (-3dB)

Level system
Real-time sampling rate: Single 1GSa / s, dual-channel 500MSa / s
Equivalent sampling rate: 25GSa / s
Time base accuracy: ± 100ppm (any time interval greater than 1ms)
Horizontal scan range: 2.5nS/DIV - 50S/DIV
             Scan: 100mS/DIV ~ 50S/DIV (1-2.5-5 order)

X-Y model
X-Axis Input / Y-axis input: channel 1 (CH1) / Channel 2 (Ch2)
Phase Shift: ± 3Degrees
Sampling frequency: XY a breakthrough in the traditional low-end oscilloscope limited 1MSa / s sampling rate limitations, support 25KSa / s ~ 100Msa / s sampling rate (1-2.5-5 order) adjustable

Measurement system
Automatic measurement (32 species): maximum, minimum, peak to peak, amplitude, top value, bottom value, period average, mean, cycle rms, root mean square, rising radical, radical decline, before rising shock, drop front shock, rise time, fall time, frequency, period, pulse width, positive pulse, negative pulse width, positive duty cycle, negative duty cycle, phase, FRR, FRF, FFR, FFF, LRR, LRF , LFR, LFF
Cursor measurements: Manual, tracking, automatic three cursor measurement

Trigger system
Trigger types: Edge, Pulse, Video, Slope, Alternate
Trigger source: CH1, CH2, EXT, EXT / 5, AC Line
Trigger mode: Auto, Normal, Single
Trigger coupling: DC, AC, LF Reject, HF Reject
Trigger Level Range: CH1, CH2: 6 from the center of the screen grid; EXT: ± 1.2V; EXT / 5: ± 6V
Trigger displacement: the pre-trigger memory depth / (2 * sample rate)), delayed trigger 260 DIV
Holdoff range: 100ns-1.5s
Edge trigger: edge type: up, down, up & down

Trigger pulse width
Trigger mode: (greater than, less than, equal to) is the pulse width, (greater than, less than, equal to) the negative pulse width
Pulse width: 20ns-10s

Video trigger
Support signal standard: PAL / SECAM, NTSC
Hair conditions: the odd field, even field, all lines, designated line

Slope: (greater than, equal to, less than) a positive slope (greater than, equal to, less than) the negative slope; time settings: 20ns-10s
Alternate Trigger: CH1 Trigger Type Edge, Pulse, Video, Slope; CH2 Trigger Type Edge, Pulse, Video, Slope

Control panel features
Auto Setup: Auto Setup function automatically adjusts the vertical, horizontal, and trigger location system
Save / Recall: 2 sets of reference waveforms, 20 of the sets, 20 sets of waveform within the Save / Recall function; external U disk storage function

Hardware frequency counter
Reading resolution: 6
Range: DC coupling, the maximum bandwidth from 10Hz to
Signal Type: applies to all available trigger signal (pulse width trigger and video trigger excluded)

General Technical Specifications
Display system
Display Type: TFT TFT 7 ?? (178mm) LCD Monitor
Display Resolution: 480 (horizontal) pixels × 234 (vertical) pixels
Display color: 64K colors
Contrast Ratio (typical) 150: 1
Background intensity (typical): 300 nit
Waveform display range: 8x12 & 8 × 18 grid cells
Display Mode: point, vector
Afterglow: Off, 1 sec, 2 sec, 5 sec, infinite
Menu is displayed: 2 seconds, 5 seconds, 10 seconds, 20 seconds, unlimited
Screen protection: off, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 5 hours
Interface options: classic, modern, traditional, simple
Interpolation method: Sin (x) / x interpolation, linear interpolation
Screen color mode: normal, inverted
Display Language: Simplified Chinese, Traditional Chinese, English, French, German, Russian, Spanish, Portuguese, Arabic, Japanese, Korean, Italian

Power supply
Supply voltage :100-240 VAC, CAT II, ??Automatic choice
AC power frequency range: 45Hz to 440Hz
Power consumption: 50VA Max

Work: 10 ? to +40 ?
Does not work: 85% RH, 65 ?, 24 ??
Cooling: forced cooling fan
Work: 85% RH, 40 ?, 24 ??
Does not work: 85% RH, 65 ?, 24 ??
Work: 3000 m
Does not work: 15,266 m

Routine maintenance and cleaning
Routine maintenance or place instruments, do not make the liquid crystal display prolonged exposure to direct sunlight.

2. avoid damaging the instrument or probes, do not place mist, liquid or solvent.
According to the instrument and operating conditions regularly to check the probe. Please click the following procedure to clean the outer surface of the instrument:
(1) Use a soft cloth to wipe the dust instrument and probe. When cleaning the LCD, be careful not to scratch the clear plastic protective screen.
(2) Use a soft cloth dampened with clean water, equipment, power off status. To more thoroughly clean, you can use 75% isopropyl alcohol water solvent.

3. To prevent damage to the surface of the instrument or probes, do not use any abrasive cleaning agents or chemical agents. prior to use, make sure the instrument has been dried to prevent moisture or personal injury caused by electrical short circuit.

  User Manual
  Warranty card
  1:1 / 10:1 probe two
  Meet the standards of your country's power cord
  USB cable
  CD-ROM (containing EasyScope3.0 computer software systems)

Add to Cart:

  • Model: SH480230
  • Shipping Weight: 470 gram